PSA Nitrogen Generator

Where the air is always on

nitrogen generator

PSA Nitrogen Generator

Working Pressure: 0.05-1.0Mpa

Free Air Delivery: 1-3000 Nm³/h

Dew Point Temperature: ≤-40℃

PSA Nitrogen Generator
 

●The unique pressure swing adsorption nitrogen production process is adopted to improve the nitrogen recovery rate and the utilization rate of carbon molecular sieve.
●Unique tower design and molecular sieve filling technology to ensure the service life of molecular sieve long cycle.
●Unique air pretreatment and retreatment filtration device to ensure that the molecular sieve is not polluted by oil for a long time.
●Unique silencer device design, which can control the exhaust noise below 75dB.
●Adopt humanized touch man-machine interface, automatic control, simple operation.
●Adopt one million frequent switching trouble-free special valves to ensure the stable operation of the system.

Model SpecificationsNitrogen production
(Nm³/h)
Voltag
(V/Hz)
Motor Power
(kW)
purity
(%)
Air pressure
(Mpa)
Nitrogen production pressure
(Mpa)
Dimension
(mm)
NXN-3535W≥99.50.80.6530*560*1100
NXN-51055W≥99.50.80.6530*560*1350
NXN-5(high profile)2050.5kW≥99.50.80.61300*710*1350
NXN-1030101kW≥99.50.80.1-0.651400*1150*1800
NXN-1540151.5kW≥99.50.80.1-0.651450*1200*1800
NXN-2050202kW≥99.50.80.1-0.651450*1200*1800
NXN-3060302.5kW≥99.50.80.1-0.651650*1250*1800

NXN-29:

serial numberFAD (Nm³/h)Voltag
(V/Hz)
Motor Power
(kW)
Import
(DN)
Outlet
(DN)
Operating temperature(°C)dew point
(°C)
oxygen content
(%)
air consumption
(Nm³/min)
152205011510room temperature-4010.25
2102205011510room temperature-4010.5
3202205012015room temperature-4011
4302205012015room temperature-4011.5
5402205012515room temperature-4012
6502205012520room temperature-4012.5
7602205012520room temperature-4013
8702205013220room temperature-4013.54
9802205013220room temperature-4014
10902205014025room temperature-4014.5
111002205014025room temperature-4015
121102205014025room temperature-4015.5
131202205014025room temperature-4016
141402205014032room temperature-4017
151502205014032room temperature-4017.5
161602205015032room temperature-4018
171802205015032room temperature-4019
182002205015040room temperature-40110
192502205015040room temperature-40112.5
203002205016540room temperature-40115
213502205016540room temperature-40117.5
224002205016550room temperature-40120
234502205016550room temperature-40122.5
245002205016550room temperature-40125
255502205018050room temperature-40127.5

NXN-39:

serial numberFAD
(Nm³/h)
Voltag
(V/Hz)
Motor Power
(kW)
Import
(DN)
Outlet
(DN)
Operating temperature(°C)dew point
(°C)
oxygen content
(%)
air consumption
(Nm³/min)
152205011510room temperature-500.10.38
2102205011510room temperature-500.10.75
3202205012015room temperature-500.11.5
4302205012515room temperature-500.12.25
5402205012515room temperature-500.13
6502205014020room temperature-500.13.75
7602205014020room temperature-500.14.5
8702205014020room temperature-500.15.25
9802205014020room temperature-500.16
10902205014025room temperature-500.16.75
111002205014025room temperature-500.17.5
121102205015025room temperature-500.18.25
131202205015025room temperature-500.19
141402205015020room temperature-500.110.5
151502205015020room temperature-500.111.25
161602205015020room temperature-500.112
171802205015020room temperature-500.113.5
182002205016525room temperature-500.115
192502205016525room temperature-500.118.75
203002205016525room temperature-500.122.5

NXN-49:

serial numberFAD
(Nm³/h)
Voltag
(V/Hz)
Motor Power
(kW)
Import
(DN)
Outlet
(DN)
Vent
(DN)
Operating temperature(°C)dew point
(°C)
oxygen content
(%)
air consumption
(Nm³/min)
1522050115106room temperature-550.010.58
21022050120106room temperature-550.011.17
320220501251510room temperature-550.012.33
430220501251510room temperature-550.013.5
540220501321515room temperature-550.014.67
650220501402015room temperature-550.015.83
760220501402015room temperature-550.017
870220501402015room temperature-550.018.17
980220501402015room temperature-550.019.33
1090220501502515room temperature-550.0110.5
11100220501502515room temperature-550.0111.67
12110220501502515room temperature-550.0112.83
13120220501502515room temperature-550.0114
14140220501653220room temperature-550.0116.33
15150220501653220room temperature-550.0117.5
16160220501653220room temperature-550.0118.67
17180220501653220room temperature-550.0121
18200220501654025room temperature-550.0123.33
19250220501804025room temperature-550.0129.17

NXN-295:

serial numberFAD
(Nm³/h)
Voltag
(V/Hz)
Motor Power
(kW)
Import
(DN)
Outlet
(DN)
Vent
(DN)
Operating temperature(°C)dew point
(°C)
oxygen content
(%)
air consumption
(Nm³/min)
1522050115106room temperature-450.50.28
21022050115106room temperature-450.50.57
320220501201510room temperature-450.51.13
430220501201510room temperature-450.51.7
540220501251515room temperature-450.52.27
650220501252015room temperature-450.52.83
760220501252015room temperature-450.53.4
870220501322015room temperature-450.53.97
980220501322015room temperature-450.54.53
1090220501402515room temperature-450.55.1
11100220501402515room temperature-450.55.67
12110220501402515room temperature-450.56.23
13120220501402515room temperature-450.56.8
14140220501403220room temperature-450.57.93
15150220501403220room temperature-450.58.5
16160220501503220room temperature-450.59.07
17180220501503220room temperature-450.510.2
18200220501504025room temperature-450.511.33
19250220501504025room temperature-450.514.17
20300220501654025room temperature-450.517

Nitrogen analyzer

●Temperature Range: Ambient to 450 °C / 842 °F;
●Temperature Stability: ± 0.5 °C;
●Temperature Precision: ± 0.5 °C;
●Process nitrogen anlyzer ,Core components imported from Germany.

Nitrogen analyzer

Pneumatic valves

●The valve body adopts a one-piece design to avoid possible leakage caused by the connection of the middle flange;
●The valve stem and the spool are connected by splines, which has good alignment, large bearing torque, eliminates the gap, and improves the valve adjustment accuracy;
●The upper and lower valve stems are fixed by self-lubricating bearings, which has high rotation accuracy and good transmission stability.

Pneumatic Angle seat valve

Solenoid valves

●Patented technology products, can last for a long time to power on for 365 days to replace normally open valves;
●Adopt diaphragm structure, low requirements for medium cleanliness;
●The valve flow coefficient is 10% higher than that of ordinary valves;
●Adopt special sealing structure and imported synthetic rubber seal without leakage.

Solenoid valve
PSA Nitrogen Generator - Nanxiang

Frequently Asked Questions

What is two-stage air compressor?

Two-stage compression reduces the compression ratio of each stage and improves volumetric efficiency. Compared to single-stage, the reduced compression ratio of each stage of a two-stage compressor improves volumetric efficiency and reduces the internal and external leakage of each stage.

For example, single-stage compression screw machine rotor: the pressure at the inlet end is about 1 bar of atmospheric pressure, compressed by the rotor to an outlet pressure of 8 bar, the compression ratio of the compression process is 8/1, that is, the single-stage compressor compression ratio of 8. While the pressure at the inlet end of the dual-stage is about 1 bar of atmospheric pressure, compressed by the first-stage rotor to an outlet pressure of about 3 bar, and then into the second-stage rotor compression to enhance the pressure to the required 8 bar The compression ratio of the first stage low pressure rotor is about 3, and the compression ratio of the second stage high pressure rotor is 8/3 ≈ 2.67, i.e. the compression ratio of the second stage is about 2.67. The maximum compression ratio of the two-stage compression rotor system is about 3.

How does a two-stage air compressor work?

A two-stage air compressor works by compressing air in two stages. In the first stage, air is compressed to an intermediate pressure and then sent to a second cylinder where it is compressed to the final desired pressure. This allows for higher efficiency and greater power output compared to a single-stage compressor.

What are the tips for starting up the two-stage air compressor?

 First, check the refrigerant pressure and ensure that the cold dryer and suction dryer are working properly. Also, make sure that the air compressor’s storage tank and filters are draining properly. Then, open the valves between the storage tank, dryers, filters, and the air compressor to ensure smooth airflow.

Next, check the oil level and look for any leaks or obstacles around the machine. If it’s a water-cooled machine, open the cooling water valve and pump, and confirm that the water pressure is normal. Finally, turn on the power and start the machine. If it has been idle for a while, start it a few times before running it continuously to avoid unnecessary malfunctions such as overheating or overload.

You May Also Like

variable speed rotary screw air compressor

S-Series Two Stage Screw Compressors

0.8-1.3 MPa
4.2-75.32 m³/min
30-355 kW, 40-476 hp
Two-stage variable speed rotary screw air compressor

S-Series Low Pressure Two Stage Screw Compressors

0.4-0.5MPa
10.5-65 m³/min
37-250 kW, 50hp-335hp
Low Pressure one-stage-scale

T-Series Low Pressure Screw Compressors

0.15-0.4 MPa
12.8-71 m³/min
30-280 kW, 40-375 hp
PSA Nitrogen Generator - Nanxiang

G-series Screw Compressors

0.7-1.3 MPa
0.8-67.5 m³/min
7.5-355 kW/ 10-475 hp

Request a Quote / Support