PSA Nitrogen Generator
Working Pressure: 0.05-1.0Mpa
Free Air Delivery: 1-3000 Nm³/h
Dew Point Temperature: ≤-40℃
- Benefits
- Parameters
- Video
- Downloads
PSA Nitrogen Generator |
●The unique pressure swing adsorption nitrogen production process is adopted to improve the nitrogen recovery rate and the utilization rate of carbon molecular sieve.
●Unique tower design and molecular sieve filling technology to ensure the service life of molecular sieve long cycle.
●Unique air pretreatment and retreatment filtration device to ensure that the molecular sieve is not polluted by oil for a long time.
●Unique silencer device design, which can control the exhaust noise below 75dB.
●Adopt humanized touch man-machine interface, automatic control, simple operation.
●Adopt one million frequent switching trouble-free special valves to ensure the stable operation of the system.
Model Specifications | Nitrogen production (Nm³/h) | Voltag (V/Hz) | Motor Power (kW) | purity (%) | Air pressure (Mpa) | Nitrogen production pressure (Mpa) | Dimension (mm) |
---|---|---|---|---|---|---|---|
NXN-3 | 5 | 3 | 5W | ≥99.5 | 0.8 | 0.6 | 530*560*1100 |
NXN-5 | 10 | 5 | 5W | ≥99.5 | 0.8 | 0.6 | 530*560*1350 |
NXN-5(high profile) | 20 | 5 | 0.5kW | ≥99.5 | 0.8 | 0.6 | 1300*710*1350 |
NXN-10 | 30 | 10 | 1kW | ≥99.5 | 0.8 | 0.1-0.65 | 1400*1150*1800 |
NXN-15 | 40 | 15 | 1.5kW | ≥99.5 | 0.8 | 0.1-0.65 | 1450*1200*1800 |
NXN-20 | 50 | 20 | 2kW | ≥99.5 | 0.8 | 0.1-0.65 | 1450*1200*1800 |
NXN-30 | 60 | 30 | 2.5kW | ≥99.5 | 0.8 | 0.1-0.65 | 1650*1250*1800 |
NXN-29:
serial number | FAD (Nm³/h) | Voltag (V/Hz) | Motor Power (kW) | Import (DN) | Outlet (DN) | Operating temperature(°C) | dew point (°C) | oxygen content (%) | air consumption (Nm³/min) |
---|---|---|---|---|---|---|---|---|---|
1 | 5 | 22050 | 1 | 15 | 10 | room temperature | -40 | 1 | 0.25 |
2 | 10 | 22050 | 1 | 15 | 10 | room temperature | -40 | 1 | 0.5 |
3 | 20 | 22050 | 1 | 20 | 15 | room temperature | -40 | 1 | 1 |
4 | 30 | 22050 | 1 | 20 | 15 | room temperature | -40 | 1 | 1.5 |
5 | 40 | 22050 | 1 | 25 | 15 | room temperature | -40 | 1 | 2 |
6 | 50 | 22050 | 1 | 25 | 20 | room temperature | -40 | 1 | 2.5 |
7 | 60 | 22050 | 1 | 25 | 20 | room temperature | -40 | 1 | 3 |
8 | 70 | 22050 | 1 | 32 | 20 | room temperature | -40 | 1 | 3.54 |
9 | 80 | 22050 | 1 | 32 | 20 | room temperature | -40 | 1 | 4 |
10 | 90 | 22050 | 1 | 40 | 25 | room temperature | -40 | 1 | 4.5 |
11 | 100 | 22050 | 1 | 40 | 25 | room temperature | -40 | 1 | 5 |
12 | 110 | 22050 | 1 | 40 | 25 | room temperature | -40 | 1 | 5.5 |
13 | 120 | 22050 | 1 | 40 | 25 | room temperature | -40 | 1 | 6 |
14 | 140 | 22050 | 1 | 40 | 32 | room temperature | -40 | 1 | 7 |
15 | 150 | 22050 | 1 | 40 | 32 | room temperature | -40 | 1 | 7.5 |
16 | 160 | 22050 | 1 | 50 | 32 | room temperature | -40 | 1 | 8 |
17 | 180 | 22050 | 1 | 50 | 32 | room temperature | -40 | 1 | 9 |
18 | 200 | 22050 | 1 | 50 | 40 | room temperature | -40 | 1 | 10 |
19 | 250 | 22050 | 1 | 50 | 40 | room temperature | -40 | 1 | 12.5 |
20 | 300 | 22050 | 1 | 65 | 40 | room temperature | -40 | 1 | 15 |
21 | 350 | 22050 | 1 | 65 | 40 | room temperature | -40 | 1 | 17.5 |
22 | 400 | 22050 | 1 | 65 | 50 | room temperature | -40 | 1 | 20 |
23 | 450 | 22050 | 1 | 65 | 50 | room temperature | -40 | 1 | 22.5 |
24 | 500 | 22050 | 1 | 65 | 50 | room temperature | -40 | 1 | 25 |
25 | 550 | 22050 | 1 | 80 | 50 | room temperature | -40 | 1 | 27.5 |
NXN-39:
serial number | FAD (Nm³/h) | Voltag (V/Hz) | Motor Power (kW) | Import (DN) | Outlet (DN) | Operating temperature(°C) | dew point (°C) | oxygen content (%) | air consumption (Nm³/min) |
---|---|---|---|---|---|---|---|---|---|
1 | 5 | 22050 | 1 | 15 | 10 | room temperature | -50 | 0.1 | 0.38 |
2 | 10 | 22050 | 1 | 15 | 10 | room temperature | -50 | 0.1 | 0.75 |
3 | 20 | 22050 | 1 | 20 | 15 | room temperature | -50 | 0.1 | 1.5 |
4 | 30 | 22050 | 1 | 25 | 15 | room temperature | -50 | 0.1 | 2.25 |
5 | 40 | 22050 | 1 | 25 | 15 | room temperature | -50 | 0.1 | 3 |
6 | 50 | 22050 | 1 | 40 | 20 | room temperature | -50 | 0.1 | 3.75 |
7 | 60 | 22050 | 1 | 40 | 20 | room temperature | -50 | 0.1 | 4.5 |
8 | 70 | 22050 | 1 | 40 | 20 | room temperature | -50 | 0.1 | 5.25 |
9 | 80 | 22050 | 1 | 40 | 20 | room temperature | -50 | 0.1 | 6 |
10 | 90 | 22050 | 1 | 40 | 25 | room temperature | -50 | 0.1 | 6.75 |
11 | 100 | 22050 | 1 | 40 | 25 | room temperature | -50 | 0.1 | 7.5 |
12 | 110 | 22050 | 1 | 50 | 25 | room temperature | -50 | 0.1 | 8.25 |
13 | 120 | 22050 | 1 | 50 | 25 | room temperature | -50 | 0.1 | 9 |
14 | 140 | 22050 | 1 | 50 | 20 | room temperature | -50 | 0.1 | 10.5 |
15 | 150 | 22050 | 1 | 50 | 20 | room temperature | -50 | 0.1 | 11.25 |
16 | 160 | 22050 | 1 | 50 | 20 | room temperature | -50 | 0.1 | 12 |
17 | 180 | 22050 | 1 | 50 | 20 | room temperature | -50 | 0.1 | 13.5 |
18 | 200 | 22050 | 1 | 65 | 25 | room temperature | -50 | 0.1 | 15 |
19 | 250 | 22050 | 1 | 65 | 25 | room temperature | -50 | 0.1 | 18.75 |
20 | 300 | 22050 | 1 | 65 | 25 | room temperature | -50 | 0.1 | 22.5 |
NXN-49:
serial number | FAD (Nm³/h) | Voltag (V/Hz) | Motor Power (kW) | Import (DN) | Outlet (DN) | Vent (DN) | Operating temperature(°C) | dew point (°C) | oxygen content (%) | air consumption (Nm³/min) |
---|---|---|---|---|---|---|---|---|---|---|
1 | 5 | 22050 | 1 | 15 | 10 | 6 | room temperature | -55 | 0.01 | 0.58 |
2 | 10 | 22050 | 1 | 20 | 10 | 6 | room temperature | -55 | 0.01 | 1.17 |
3 | 20 | 22050 | 1 | 25 | 15 | 10 | room temperature | -55 | 0.01 | 2.33 |
4 | 30 | 22050 | 1 | 25 | 15 | 10 | room temperature | -55 | 0.01 | 3.5 |
5 | 40 | 22050 | 1 | 32 | 15 | 15 | room temperature | -55 | 0.01 | 4.67 |
6 | 50 | 22050 | 1 | 40 | 20 | 15 | room temperature | -55 | 0.01 | 5.83 |
7 | 60 | 22050 | 1 | 40 | 20 | 15 | room temperature | -55 | 0.01 | 7 |
8 | 70 | 22050 | 1 | 40 | 20 | 15 | room temperature | -55 | 0.01 | 8.17 |
9 | 80 | 22050 | 1 | 40 | 20 | 15 | room temperature | -55 | 0.01 | 9.33 |
10 | 90 | 22050 | 1 | 50 | 25 | 15 | room temperature | -55 | 0.01 | 10.5 |
11 | 100 | 22050 | 1 | 50 | 25 | 15 | room temperature | -55 | 0.01 | 11.67 |
12 | 110 | 22050 | 1 | 50 | 25 | 15 | room temperature | -55 | 0.01 | 12.83 |
13 | 120 | 22050 | 1 | 50 | 25 | 15 | room temperature | -55 | 0.01 | 14 |
14 | 140 | 22050 | 1 | 65 | 32 | 20 | room temperature | -55 | 0.01 | 16.33 |
15 | 150 | 22050 | 1 | 65 | 32 | 20 | room temperature | -55 | 0.01 | 17.5 |
16 | 160 | 22050 | 1 | 65 | 32 | 20 | room temperature | -55 | 0.01 | 18.67 |
17 | 180 | 22050 | 1 | 65 | 32 | 20 | room temperature | -55 | 0.01 | 21 |
18 | 200 | 22050 | 1 | 65 | 40 | 25 | room temperature | -55 | 0.01 | 23.33 |
19 | 250 | 22050 | 1 | 80 | 40 | 25 | room temperature | -55 | 0.01 | 29.17 |
NXN-295:
serial number | FAD (Nm³/h) | Voltag (V/Hz) | Motor Power (kW) | Import (DN) | Outlet (DN) | Vent (DN) | Operating temperature(°C) | dew point (°C) | oxygen content (%) | air consumption (Nm³/min) |
---|---|---|---|---|---|---|---|---|---|---|
1 | 5 | 22050 | 1 | 15 | 10 | 6 | room temperature | -45 | 0.5 | 0.28 |
2 | 10 | 22050 | 1 | 15 | 10 | 6 | room temperature | -45 | 0.5 | 0.57 |
3 | 20 | 22050 | 1 | 20 | 15 | 10 | room temperature | -45 | 0.5 | 1.13 |
4 | 30 | 22050 | 1 | 20 | 15 | 10 | room temperature | -45 | 0.5 | 1.7 |
5 | 40 | 22050 | 1 | 25 | 15 | 15 | room temperature | -45 | 0.5 | 2.27 |
6 | 50 | 22050 | 1 | 25 | 20 | 15 | room temperature | -45 | 0.5 | 2.83 |
7 | 60 | 22050 | 1 | 25 | 20 | 15 | room temperature | -45 | 0.5 | 3.4 |
8 | 70 | 22050 | 1 | 32 | 20 | 15 | room temperature | -45 | 0.5 | 3.97 |
9 | 80 | 22050 | 1 | 32 | 20 | 15 | room temperature | -45 | 0.5 | 4.53 |
10 | 90 | 22050 | 1 | 40 | 25 | 15 | room temperature | -45 | 0.5 | 5.1 |
11 | 100 | 22050 | 1 | 40 | 25 | 15 | room temperature | -45 | 0.5 | 5.67 |
12 | 110 | 22050 | 1 | 40 | 25 | 15 | room temperature | -45 | 0.5 | 6.23 |
13 | 120 | 22050 | 1 | 40 | 25 | 15 | room temperature | -45 | 0.5 | 6.8 |
14 | 140 | 22050 | 1 | 40 | 32 | 20 | room temperature | -45 | 0.5 | 7.93 |
15 | 150 | 22050 | 1 | 40 | 32 | 20 | room temperature | -45 | 0.5 | 8.5 |
16 | 160 | 22050 | 1 | 50 | 32 | 20 | room temperature | -45 | 0.5 | 9.07 |
17 | 180 | 22050 | 1 | 50 | 32 | 20 | room temperature | -45 | 0.5 | 10.2 |
18 | 200 | 22050 | 1 | 50 | 40 | 25 | room temperature | -45 | 0.5 | 11.33 |
19 | 250 | 22050 | 1 | 50 | 40 | 25 | room temperature | -45 | 0.5 | 14.17 |
20 | 300 | 22050 | 1 | 65 | 40 | 25 | room temperature | -45 | 0.5 | 17 |
Nitrogen analyzer
●Temperature Range: Ambient to 450 °C / 842 °F;
●Temperature Stability: ± 0.5 °C;
●Temperature Precision: ± 0.5 °C;
●Process nitrogen anlyzer ,Core components imported from Germany.

Pneumatic valves
●The valve body adopts a one-piece design to avoid possible leakage caused by the connection of the middle flange;
●The valve stem and the spool are connected by splines, which has good alignment, large bearing torque, eliminates the gap, and improves the valve adjustment accuracy;
●The upper and lower valve stems are fixed by self-lubricating bearings, which has high rotation accuracy and good transmission stability.

Solenoid valves
●Patented technology products, can last for a long time to power on for 365 days to replace normally open valves;
●Adopt diaphragm structure, low requirements for medium cleanliness;
●The valve flow coefficient is 10% higher than that of ordinary valves;
●Adopt special sealing structure and imported synthetic rubber seal without leakage.

- Share your requirements for expert evaluation (multilingual support).
- Get customized solution, including IP level, air end and parts, screen language, remote control, appearance, voltage and temperature adaptation, etc.
- Production started after order confirmation (standard production time: 20-25 days).
- Rigorous quality testing before shipping.
- Lifelong technical support, original maintenance parts support, and up to 10-year warranty on the air end.

Frequently Asked Questions
Two-stage compression reduces the compression ratio of each stage and improves volumetric efficiency. Compared to single-stage, the reduced compression ratio of each stage of a two-stage compressor improves volumetric efficiency and reduces the internal and external leakage of each stage.
For example, single-stage compression screw machine rotor: the pressure at the inlet end is about 1 bar of atmospheric pressure, compressed by the rotor to an outlet pressure of 8 bar, the compression ratio of the compression process is 8/1, that is, the single-stage compressor compression ratio of 8. While the pressure at the inlet end of the dual-stage is about 1 bar of atmospheric pressure, compressed by the first-stage rotor to an outlet pressure of about 3 bar, and then into the second-stage rotor compression to enhance the pressure to the required 8 bar The compression ratio of the first stage low pressure rotor is about 3, and the compression ratio of the second stage high pressure rotor is 8/3 ≈ 2.67, i.e. the compression ratio of the second stage is about 2.67. The maximum compression ratio of the two-stage compression rotor system is about 3.
A two-stage air compressor works by compressing air in two stages. In the first stage, air is compressed to an intermediate pressure and then sent to a second cylinder where it is compressed to the final desired pressure. This allows for higher efficiency and greater power output compared to a single-stage compressor.
First, check the refrigerant pressure and ensure that the cold dryer and suction dryer are working properly. Also, make sure that the air compressor’s storage tank and filters are draining properly. Then, open the valves between the storage tank, dryers, filters, and the air compressor to ensure smooth airflow.
Next, check the oil level and look for any leaks or obstacles around the machine. If it’s a water-cooled machine, open the cooling water valve and pump, and confirm that the water pressure is normal. Finally, turn on the power and start the machine. If it has been idle for a while, start it a few times before running it continuously to avoid unnecessary malfunctions such as overheating or overload.