Refrigerated Compressed Air Dryer

Where the air is always on

Refrigerated Compressed Air Dryer

Inlet Pressure: 0.4 – 1.6 Mpa

Rated Air Capacity: 1.5 – 550 m³/min

Compressor Power: 0.35 – 90 kW

Nanxiang refrigerated compressed air dryer is a reliable, efficient and stable device designed to reduce humidity when drying compressed air.
● Equipped with a powerful and efficient cooling control system (thermostatic bypass) to ensure stable exhaust pressure dew point and prevent ice blockages from occurring.

● Reduces the number of alignments or line leaks, in turn reducing energy consumption, as well as the need for repairs on pneumatic tools and pipes.

High temperature air-cooled dryer:

Project/ModelNX-15HFNX-2.6HFNX-3.8HFNX-5.5HFNX-6.9HFNX-8.5HFNX-11HFNX-14.9HFNX-17HFNX-22HFNX-24.5HFHX-28HFNX-34HFNX-45HFNX-55HFNX-65HFNX-75HFNX-85HFNX-110HF
Rated Air Capacity (m³/min)152.69466.98.51114.917222528344555657585110
Power supply (V/Hz)lph220v50hzlph220v50hzlph220v50hzlph220v50hzlph220v50hzlph220v50hzlph220v50hz3ph380v50hz3ph380v50hz3ph380v50hz3ph380v50hz3ph380v50hz3ph380v50hz3ph380v50hz3ph380v50hz3ph380v50hz3ph380v50hz3ph380v50hz3ph380v50hz
Power(kW)0.350.450.65000121.651.9432.943.754.24.457.358.829.9211.0311.0314.70
RefrigerantR134aR134aR134aR134aR134aR134aR134aR134aR134aR134aR134aR134aR134aR134aR134aR134aR134aR134aR134a
Air takeover caliberR1R1R1R1-1/2R1-1/2R1-1/2R2R2DN65DN65DN80DN80DN80DN100DN100DN125DN125DN150DN150
Dimension (H) (mm)50050076076589589510051005100512501250160016001600l8002100210021002650
Dimension (W) (mm)2802804304354854855855855856306307507507509001010101010101050
Dimension (H) (mm)5305306607658758751130113011301300130014001400140016201710171017102100
Weight (kg)3239678093100180200250280380430480520670860110013001500

High temperature water-cooled cold dryer:

Project \ModelNX-11HWNX-14.9HWNX-17HWNX-22HWNX-24.5HWNX-28HWNX-34HWNX-45HWNX-55HWNX-65HWNX-75HWNX-85HWNX-110HWNX-140HWNX-168HWNX-220HWNX-280HWNX-320HWNX-460HWNX-550HW
Rated Air Capacity
(m³/min)
1114.9172224.5283445.055657585110140168220280320460550
Power supply(V/Hz)lph220v50hz3ph380v50hz3ph380v50hz3ph380v50hz3ph380v50hz3ph380v50hz3ph380v50hz3ph380v50hz3ph380v50hz3ph380v50hz3ph380v50hz3ph380v50hz3ph380v50hz3ph380v50hz3ph380v50hz3ph380v50hz3ph380v50hz3ph380v50hz3ph380v50hz3ph380v50hz
Power(kw)1.942.752.943.754.24.45.27.358.829.9211.0311.0314.718.4303650558090
Refrigerant TypeR22 or R407CR22 or R407CR22 or R407CR22 or R407CR22 or R407CR22 or R407CR22 or R407CR22 or R407CR22 or R407CR22 or R407CR22 or R407CR22 or R407CR22 or R407CR22 or R407CR22 or R407CR22 or R407CR22 or R407CR22 or R407CR22 or R407CR22 or R407C
Air takeover caliberR2R2DN65DN65DN80DN80DN80DN100DN100DN125DN125DN150DN150DN150DN200DN200DN250DN250DN300DN300
Condenser Water Pipe DiameterRc1/2Rc1/2Rc1Rc1Rc1-1/2Rc1-1/2Rc1-1/2Rc1-1/2Rc1-1/2Rc1-1/2Rc1-1/2Rc1-1/2Rc2Rc2DN65DN65DN65DN80DN100DN125
Dimensions (L) (mm)10051005100512501250160016001600190019001900190021002100270033003300330045004500
Dimensions (W) (mm)585585585630630750750750100010001000100012001200150015001500150020002000
Dimensions (H) (mm)11301130113013001300140014001400160016001600160018001800220023502400250030003000
Weight (kg)1601702002804605006507008009501000125019002450300033003700400049005100

Refrigerated Air Dryer - Nanxiang

Frequently Asked Questions

What is a refrigerated compressed air dryer?

A refrigerated compressed air dryer is a device that removes moisture from compressed air by cooling it down to a temperature where the water vapor condenses and can be removed. This helps prevent corrosion and damage to pneumatic tools and equipment, and ensures that the compressed air is clean and dry for use in various industrial applications.

How does a refrigerated compressed air dryer work?

A refrigerated compressed air dryer works by cooling the compressed air to a temperature where water vapor condenses into liquid form and can be removed from the air stream. The compressed air enters the dryer and passes through a heat exchanger where it is cooled by refrigerant. The cooled air then enters a separator where the condensed water is removed and drained out of the system. The dry air is then reheated and exits the dryer.

How to repair a refrigerated compressed air dryer?

Repairing a refrigerated compressed air dryer can be a complex process and should only be attempted by a trained professional. However, some common troubleshooting steps include checking for power and refrigerant leaks, cleaning the condenser and evaporator coils, and replacing any faulty components such as the compressor or fan motor. It is important to follow Nanxiang guidelines and safety precautions when attempting any repairs.

You May Also Like

variable speed rotary screw air compressor

S-Series Two Stage Screw Compressors

0.8-1.3 MPa
4.2-75.32 m³/min
30-355 kW, 40-476 hp
Two-stage variable speed rotary screw air compressor

S-Series Low Pressure Two Stage Screw Compressors

0.4-0.5MPa
10.5-65 m³/min
37-250 kW, 50hp-335hp
Low Pressure one-stage-scale

T-Series Low Pressure Screw Compressors

0.15-0.4 MPa
12.8-71 m³/min
30-280 kW, 40-375 hp
Refrigerated Air Dryer - Nanxiang

G-series Screw Compressors

0.7-1.3 MPa
0.8-67.5 m³/min
7.5-355 kW/ 10-475 hp

Request a Quote / Support